Eos Group

Bulletin

High Voltage Knowledgebase

Error in Assembly G10.60 Trench Excavation-Type 4 Soil-Depth 10-15 ft-All Wood

The calculation for Wood Wales is incorrect and results in significantly high quantities of wale length.

To fix the assembly:

Edit the assembly in the database

Right click to Edit Calculation for the Wood Sheeting Wales item

Right click the formula in the calculation to edit the formula: TrenchWoodWalesLen10To15Ft

Replace the embedded formula in that calculation named TrenchExcavationVolume10To15FtD

With the formula TrenchWoodWales10To15FtD

Save the changed formula, the calculation, and the assembly.

 

 

The new formula content should look like this: